256 sin/cos periods |
150 to 2048 pulses per revolution |
Short-wave accuracy (transducer and tooth errors)
|
360° x 0.006/pulse number |
Long-wave accuracy (concentricity error)
|
± 0.015° |
|
|
|
|
|
10 to 30 V DC |
Power consumption without load
|
|
|
|
|
|
|
|
|
High: UB - 1 V, low: < 1.0 V
|
Maximum permissible cable length
|
100 m (consider voltage drop on supply cable) |
|
|
|
|
stainless steel, X12CrMoS17-1,4104
|
|
|
|
Permissible coupling offset axial lateral
|
± 1.3mm ± 0.2mm
|
|
|
|
|
|
> 50 years (calculated). Due to the limited grease service life, the bearings should be replaced after a maximum mileage of 1,200,000 km (rail vehicles) or every 8 years.
|
|
|
Working temperature range (DIN 32876)
|
|
Operating and storage temperature range (DIN 32876)
|
|
Degree of protection (EN 60529)
|
IP 67 (hollow shaft side: corresponding to the degree of protection of the motor or gear unit)
|
Vibration resistance (DIN IEC 600068, Part 2-6)
|
|
Shock resistance (DIN IEC 60068, Part 2-27)
|
|
Electromagnetic compatibility
|
Industrial applications: EN/IEC 61000-6-1 to 4 Rail vehicles: EN 50121-3-2
|
Dielectric strength (EN 60439-1)
|
|