Farbthema

Lenord+Bauer Finding Solutions. Founding Trust.
Visit us: IMTOF, 02.-06.04.2026, Chennai, India
Visit us: Rail Link, 09.04.2026, Dublin, Ireland
Visit us: Simtos, 13.-17.04.2026, Seoul, South Korea
Visit us: CCMT, 21.-25.04.2026, Shanghai, China, booth W5-A183
Visit us: Offshore Technology, 04.-07.05.2026, Houston, USA
Visit us: INTERPACK, 07.-13.05.2026, Düsseldorf, Germany, Packaging Valley Joint Booth
Visit us: All About Automation, 02.-03.06.2026, Hamburg, Germany
Visit us: Coiltech, 10.-11.06.2026, Novi, USA
Visit us: Automate, 22.-25.06.2026, Chicago, USA
Visit us: AMTEX, 24.-27.07.2026, Delhi, India
Visit us: Drone Days, 26.-28.08.2026, Bremen/ Oldenburg, Germany
Visit us: SMM, 01.-04.09.2026, Hamburg, Germany
Visit us: InnoTrans, 22.-25.09.2026, Berlin, Germany, hall 27, booth 561
Visit us: All About Automation, 15.10.2026, Düsseldorf, Germany
Visit us: Pack Expo, 18.-21.10.2026, Las Vegas, USA

SeGMo-Assist – GEL SEROT

Rotary sensor for the position display GEL SEPODL

  • Magnetic-absolute measuring system to facilitate manual adjustment procedures
  • Intended for use with the GEL SEPODL position display.

Technical information

Features

  • Housing material: PA 12 black
  • Operating temperature range: 0 °C to +60 °C [32 °F to 140 °F]
  • Degree of protection: IP 65
  • Batteryless , magnetic-absolute multiturn encoder
  • Through hollow shaft 20H7 mm [0.79H7 in], stainless steel
  • cULus Component Recognition

Advantages

  • Not sensitive to EMC interference
  • Simple cabling
  • Extremely compact for confined installation situations
  • Ready for use directly after switching on the power supply due to absolute position detection of the magnetic-absolute multiturn encoder
  • Maintenance-free electrical parts

Downloads

Downloads

Product Document Languages
GEL SEROT Technical information DE EN
Operating instructions DE/EN
Product information DE/EN

Registration required

Fields of application

  • Packaging machines
  • Food and bottling lines
  • Wood and plastic processing machines
  • General mechanical and systems engineering

Dimensional drawings

All dimensions in mm [inch]

Technical data

Electrical data

Supply voltage UB (polarity reversal protection, overvoltage protection)

20 to 30 V DC

Current consumption

≈30 mA at 24 V DC

Power consumption

Requirements for the power supply unit: Maximum supply output: 100 VA

Communication interfaces

Internal communication interface Lenord+Bauer: RS422, proprietary transmission protocol

Mechanical data

Sensor shaft

Durchgangshohlwelle: Edelstahl rostfrei, Durchmesser 20 H7 mm [0,79 H7 in]

Maximum permissible rotational speed

100 min-1 bei ED = 25 % (ED = Einschaltdauer)

Housing material

PA 12 schwarz

Housing dimensions (not including connection elements, not including torque support)

48 mm × 44.8 mm × 70 mm [1.89 in × 1.76 in × 2.76 in]

Weight

≈145 g [5.11 oz]

Encoder data

Scanning

magnetic, absolute

Measuring system detection range

In energized state: unlimited

In de-energized state: 129 revolutions

Connection elements

Communication interface and supply voltage

8-pin male connector M12, A-coded

Functional ground

6.3 mm [0.25 in] flat connector

Ambient data

Operating temperature range

0 °C to +60 °C [32 °F to 140 °F]

Storage temperature range

-20 °C to +80 °C [-4 °F to 176 °F]

Maximum relative air humidity

Condensation not permitted

Degree of protection

IP65; as per DIN EN 60529:2014-09
(Degree of protection not rated by UL!)

Dielectric strength

500 V AC; as per DIN EN 61439-1:2012-06

EMC

DIN EN 61326-1:2013-07; Class B device with immunity requirements for industrial environments

Vibration resistance

1 to 100 m/s2 [3.28. to 328.08 ft/s2], 5 to 15 Hz;
100 m/s2 [328.08 ft/s2], 15 to 159 Hz;
as per DIN EN 60068-2-6:2008-10

Shock resistance

800 m/s2 [2624.67 ft/s2], 6 ms,
as per DIN EN 60068-2-27:2010-02

Data for "cULus Recognized Component"

Housing type

Closed

Device function

Process control device

Connection to main power supply

No

Overvoltage category

II

Contamination level

2

Guards

Class III (Class SELV or PELV and limited power or LPS)

Atmospheric humidity

Maximum 80 % at temperatures up to 31 °C [87.8 °F], linear decreasing to 50 % relative atmospheric humidity at 40 °C [104 °F]

Installation altitude

≤ 2000 m [1.24 mi]

Use in wet areas

No

Device mobility

Immovable

Operating conditions

Continuous

Classification according to UL61010-1

Type 1

Approvals

European Economic Area

Conformity in accordance with EMC Directive 2014/30/EU

USA and Canada

Certification as cULus Recognized Component