Tower oscillation monitor GEL 3011

 3011.jpg

3-axes tower oscillation monitor in compact design

  • Redundant system with two independent CPUs and two oscillation monitors arranged at 45° to each other
  • Appropriate for safety application with PLd requirement as per DIN EN ISO 13849 (SIL2)

Product details

Technical dataTower oscillation monitor GEL 3011
Field of applicationin the tower of the wind turbine
Measuring range± 15 m/s2 (1,5 g approx.)
Resolution± 0.01 m/s2
Featuresmeasuring direction X, Y and Z
Accuracy± 0.05 m/s2
Housing materialaluminium anodized
Condensation permittedyes
Temperature range

-40 °C to +85 °C

Protection classIP 67
Operating voltage24 V DC ± 10 %
InterfacesCANopen, factory adjustable safety relay outputs
(each 2 NC and 2 NO), electrically isolated

Downloads

Accessories

General accessories

ArticleDescription
BK 2100CANopen connection cable 10 m, 5-pin plug / flying lead with ferrules
BK 2101CANopen connection cable 10 m, 5-pin plug / flying lead with ferrules
BK 2102CANopen connection cable 10 m, 5-pin socket / flying lead with ferrules
BK 2103CANopen connection cable 2 m, 5-pin socket / flying lead with ferrules
BK 2104CANopen connecting cable 10 m, 5-pin socket/plug
BK 2105CANopen connecting cable 2 m, 5-pin socket/plug
FS 3020CANopen, mating connector 5-pin socket, A-coded
FS 3021CANopen, mating connector 5-pin plug, A-coded
FS 3040CANopen terminating resistor M12
FS 1352Relay output mating connector, M12, 8-pin socket, A-coded
FS 1095Relay output connection cable 10 m, 8-pin socket M12 A-coded / flying lead

Stp-files

If you need stp data, then send an e-mail with the article no. to info@lenord.de.

Any Questions?